EH/0S
Vent Cap, End-of-Line

Features
Cost Effective Device
Cost Effective Device
Vent Cap Provides Protection
Against Environmental Impact (Harsh Weather Conditions, Bird Nests, etc.)
Almost Maintenance Free
Almost Maintenance Free
Certified Flow Performance Curves
Certified Flow Performance Curves
Function and Description

Weather Protection Hood for Efficient Ventilation
The PROTEGO® EH/0S vent cap allows vessels which are not pressurized to vent. This device prevents rain and dirt entering the vent line. The PROTEGO® EH/0S vent cap is not flame transmission proof. It is often used in combination with Detonation Flame Arresters, when those are used in vent lines, installed at a position which creates a long run up distance from the end of the vent line to prevent endurance burning. The PROTEGO® EH/0S will then be installed at the end of that vent line to prevent particles or rain from entering the line.
The vent cap PROTEGO® EH/0S main components are a housing (1), a weather hood (2) and a protection screen (3). The device is equipped with a fixed weather hood out of metal. The protection screen prevents particles or rain from entering the line.
Product Data
Dimensions
To select the nominal size (DN), please use the flow capacity charts on the following pages
| DN | 100 / 4" | 150 / 6" | 200 / 8" | 250 / 10" | 300 / 12" | 350 / 14" | 400 / 16" | 500 / 20" | 600 / 24" |
| a | 295 / 11.61 | 550 / 21.65 | 550 / 21.65 | 600 / 23.62 | 600 / 23.62 | 600 / 23.62 | 650 / 25.59 | 800 / 31.50 | 1000 / 39.37 |
| b | 230 / 9.06 | 240 / 9.45 | 240 / 9.45 | 325 / 12.80 | 320 / 12.60 | 335 / 13.19 | 370 / 14.57 | 385 / 15.16 | 520 / 20.47 |
Dimensions in mm / inches
Material selection
| Design | A | B |
| Housing | Steel | Stainless Steel |
| Weather hood | Stainless Steel | Stainless Steel |
Special materials upon request
Flange connection type
| EN 1092-1; Form B1 |
| ASME B16.5 CL 150 R.F. |
other types upon request
Flow Capacity Chart

The flow capacity charts have been determined with a calibrated and TÜV certified flow capacity test rig. Volume flow V in (m³/h) and CFH refer to the standard reference conditions of air ISO 6358 (20°C, 1bar). For conversion to other densities and temperatures refer to Sec. 1: “Technical Fundamentals”.
