LDA
Liquid Detonation Flame Arrester for filling lines - internal installation

Features
Low Risk
Low Risk of Fouling
Meets TRGS Requirements
TRGS = Technical Regulations for Hazardous Substances
Different Connections
Available With Different Connections
Explosion Safety
Provides Protection Against Deflagration and Stable Detonation
For Flammable Liquids
Useable for Nearly All Flammable Liquids
Low Pressure Loss
Function and Description

Prevention of Flame Spread in Tank During Ignition
The PROTEGO® LDA Series of Liquid Detonation Arresters was developed for storage tank filling lines that are not continuously filled with product and sometimes contain a combustible mixture.
The device is installed inside the tank at the end of the line and prevents the combustion from being transferred into the tank if the explosive atmosphere ignites. The liquid detonation arresters function according to the siphon principle in which the liquid product serves as a liquid barrier to flame propagation.

Reduction of Flame Propagation Speed
When a highly accelerated pipe deflagration or detonation occurs, the combustion pressure and flame propagation speed is substantially reduced by the design, converted into a low-energy deflagration, and then stopped by the remaining immersion liquid.

For Explosion Groups IIA to IIB3
The application range for the device is a product vapor/air mixture temperature of up to + 60°C / 140°F and an absolute pressure up to 1.1 bar / 15.9 psi. This covers all possible operating conditions of empty lines for flammable liquids. The liquid detonation arrester is pressure-resistant up to 10 bar / 145 psi. The device protects against nearly all flammable liquids and is approved for explosion groups IIA to IIB3 (NEC group D to C MESG ≥ 0.65 mm).
EU conformity according to the currently valid ATEX directive. Approvals according to other national/international regulations on request.
Product Data
Dimensions
To select the nominal size (DN), please use the flow capacity chart on the following pages
| DN | 25 / 1" | 32 / 1¼“ | 40 / 1½“ | 50 / 2" | 65 / 2½“ | 80 / 3" | 100 / 4" | 125 / 5" | 150 / 6" | 200 / 8" | 250 / 10" |
| a | 500 / 19.69 | 580 / 22.83 | 700 / 27.56 | 700 / 27.56 | 825 / 32.48 | 925 / 36.42 | 1050 / 41.34 | 1150 / 45.28 | 1350 / 53.15 | 1650 / 64.96 | 2000 / 78.74 |
| b | 538 / 21.18 | 620 / 24.41 | 745 / 29.33 | 745 / 29.33 | 870 / 34.25 | 975 / 38.39 | 1102 / 43.39 | 1205 / 47.44 | 1405 / 55.31 | 1712 / 67.40 | 2068 / 81.42 |
| c | 725 / 28.54 | 805 / 31.69 | 925 / 36.42 | 925 / 36.42 | 1050 / 41.34 | 1145 / 45.08 | 1270 / 50.00 | 1380 / 54.33 | 1580 / 62.20 | 1880 / 74.02 | 2300 / 90.55 |
| d | 115 / 4.53 | 140 / 5.51 | 168 / 6.61 | 168 / 6.61 | 220 / 8.66 | 245 / 9.65 | 325 / 12.80 | 356 / 14.02 | 500 / 19.69 | 600 / 23.62 | 700 / 27.56 |
| e | 50 / 1.97 | 58 / 2.28 | 65 / 2.56 | 65 / 2.56 | 95 / 3.74 | 105 / 4.13 | 135 / 5.31 | 155 / 6.10 | 200 / 7.87 | 250 / 9.84 | 300 / 11.81 |
Dimensions in mm / inches
Selection of explosion group
| MESG | Expl. Gr. (IEC / CEN) | Gas Group (NEC) |
| > 0,90 mm | IIA | D |
| ≥ 0,65 mm | IIB3 | C |
Special approvals upon request
Specification of max. operating temperature
| ≤ 60°C / 140°F | Tmaximum allowable operating temperature in °C |
| - | Designation |
higher operating temperatures upon request
Material selection for housing
| Design | A | B |
| Housing | Steel | Stainless Steel |
| Gasket | PTFE | PTFE |
Special materials upon request
Flange connection type
| EN 1092-1; Form B1 |
| ASME B16.5 CL 150 R.F. |
other types upon request
Outlet type
| Straight pipe | I |
| Beveled pipe | II |
| EN 1092-1, Form B1 or DIN 2501, Form C | III (EN or DIN) |
| ASME B16.5 CL 150 R.F. | III (ASME) |
other types upon request
Flow Capacity Chart

The volume flow V in m³/h was determined with water according to DIN EN 60534 at a temperature Tn = 20°C and an atmospheric pressure pn = 1,013 bar, kinematic viscosity v = 10-6 m²/s
To avoid electrostatic charge of flammable liquids the maximum flow is limited (refer to TRGS 727, CENELEC-Report CLC/TR 60079-32-1).